BQVVM - HARDTEC 19400
- MSDS: BQVVM
- Manufacturer: EUTECTIC CORP
- Product Name: HARDTEC 19400
- National Stock Number: 3439-00N037587
Product Identification
Product ID:HARDTEC 19400
MSDS Date:05/01/1986
FSC:3439
NIIN:00N037587
MSDS Number: BQVVM
Responsible Party
FLUSHING, NY 11358-9981
US
Emergency Phone: 718-358-4000
Info Phone: 718-358-4000
Cage: 72271
Contractor
Telephone: 704-527-9800/ 800-221-1433
Cage: 72271
Ingredients
MANGANESE (SARA III)
CAS: 7439-96-5
RTECS: OO9275000
OSHA PEL (C) 5 MG/M3 DUST
ACGIH TLV: 5 MG/M3 DUST 9293
SILICON
CAS: 7440-21-3
RTECS: VW0400000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
CARBON;(GRAPHITE, SYNTHETIC)
CAS: 7440-44-0
RTECS: FF5250100
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 2 MG/M3 TDUST; 9293
OVEREXP TO MANGANESE CMPDS MAY AFFECT CNS. SYMPS
RTECS: 9999999ZZ
DISEASE. BEHAVORIAL CHANGES IN HANDWRITING MAY ALSO
RTECS: 9999999ZZ
QUARTERLY MD EXAMS FOR EARLY DETECTION OF MANGANESE
RTECS: 9999999ZZ
STUDIES
RTECS: 9999999ZZ
HEXAVALENT CHROMIUM CMPDS HAVE AN EXCESS OF LUNG
RTECS: 9999999ZZ
CONSIDERED TO BE CARC. ABSORPTION THROUGH SKIN CAN
RTECS: 9999999ZZ
& LIVER. GOOD PRACTICE REQS REDUCTION OF EMPLOYEE
RTECS: 9999999ZZ
GOGGLES, IF NEC TO SHIELD OTHERS. AS A
RTECS: 9999999ZZ
ZONE; THEN GO TO NEXT LIGHTER SHADE WHICH GIVES
RTECS: 9999999ZZ
IRON (PEL/TLV FOR IRON OXIDE FUME AS FE)
CAS: 7439-89-6
RTECS: NO4565500
OSHA PEL 10 MG/M3
ACGIH TLV: 5 MG/M3
CHROMIUM (SARA III)
CAS: 7440-47-3
RTECS: GB4200000
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:OVEREXPOSURE TO FUMES, GASES AND
DUSTS MAY RESULT IN DISCOMFORT SUCH AS DIZZINESS, NAUSEA, OR
DRYNESS OR IRRITATION OF NOSE, THROAT OR EYES. SILICON:POSSIBLE EYE
IRRITANT. CHROMIUM:INHAL OF FUME W/CHROMIUM (VI) CMPDS CAN CAUSE
IRRIT OF RESP SYS, DMG TO LUNGS & ASTHMA LIKE SYMPS. SWALLOWING
(EFTS OF OVEREXPOSURE)
Explanation of Carcinogenicity:CHROMIUM:KNOWN CARCINOGEN (NTP), GROUP 1
(IARC).
Effects of Overexposure:HLTH HAZ:CHROMIUM (VI) SALTS CAN CAUSE SEVERE
INJURY OR DEATH. DUSTS ON SKIN CAN FORM ULCERS. EYES MAY BE BURNED
BY CHROMIUM (VI) CMPDS. ALLERG RXNS LIKELY IN SOME PEOPLE FROM
CHROMIUM CMPDS. CHRONIC: OVEREXP TO FUMES, GASES, & DUSTS MAY LEAD
TO SIDEROSIS (IRON DEPOSITS IN LUNGS) & MAY AFFECT PULM FUNCTIONS.
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN:WASH WITH SOAP & WATER. EYE:REMOVE BY IRRIGATING
W/COPIOUS AMOUNTS OF WATER FOR LEAST 15 MINUTES. INHAL:MOVE TO
WELL-VENTILATED AREA. APPLY ARTIFICIAL RESPIRATION, IF NEEDED. CALL
MD. EMPLOY FIRS T-AID TECHNIQUES RECOMMENDED BY THE AMERICAN RED
CROSS. INGEST:CALL MD IMMEDIATELY .
Fire Fighting
Flash Point:NONFLAMMABLE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:METAL POWDER DUST MAY PRESENT A FIRE OR
EXPLOSION HAZARD UNDER FAVORABLE CONDITIONS OF PARTICLE SIZE,
DISPERSION AND STRONG IGNITION SOURCE.
Accidental Release
Spill Release Procedures:CLEAN-UP BY VACUUMING, WET DUSTMOP, OR WET
CLEAN-UP. AVOID DUST GENERATION. USE AN APPROP FILTER WITH VACUUM
EQUIPMENT TO PREVENT AIRBORNE DUST LEVELS WHICH EXCEED PEL/TLV. IF
AIRBORNE DUST GENERATED, USE APPROP NIOSH/MSHA APPROVED RESP FOR
CLEANUP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:MAINTAIN EXPOSURE BELOW PEL/TLV. USE
INDUSTRIAL HYGIENE MONITORING TO ENSURE THAT USE OF PRODUCT DOES
NOT CREATE EXPOSURE EXCEEDING THE PEL/TLV.
Other Precautions:READ AND UNDERSTAND THE MANUFACTURERS INSTRUCTIONS
AND THE PRECAUTIONARY LABEL ON PRODUCT.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRABLE FUME
RESPIRATOR OR AIR SUPPLIED RESPIRATORS WHEN WORKING IN CONFINED
SPACE OR WHERE LOCAL EXHAUST OR VENTILATION DOES NOT KEEP EXPOSURE
BELOW RECOMMENDED EXPOSURE LI MIT.
Ventilation:USE ENOUGH GENERAL VENT & LOCAL EXHAUST AT WORK SITE TO
KEEP FUMES, GASES/DUSTS FROM WORKER'S BREATHING ZONE & GEN AREA.
Protective Gloves:WELDER'S GLOVES.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:ARM PROTECTORS, APRONS, HATS, SHOULDER
PROTECTION, AS WELL AS DARK SUBSTANTIAL CLOTHING. PROVIDE PROT
SCREENS & (ING 13)
Work Hygienic Practices:TRAIN WORKER TO KEEP HIS HEAD OUT OF THE FUMES.
Supplemental Safety and Health
HAZ DECOMP PRODS:PLUS THOSE FROM BASE METAL & COATING, ETC. AS NOTED.
REASONABLY EXPECTED CONSTITUENTS OF FUME WOULD INCLUDE COMPLEX
OXIDES OF METALS LISTED. GASEOUS RXN PRODS MAY INCL CARBON MONOXIDE
& CARBON DIOXIDE. OZONE & NITROGEN OXIDES MAY BE FORMED BY
RADIATION. EFTS OF OVEREXP:MANGANESE:LONG TERM (ING 6)
Chemical Properties
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:DECOMP PRODS OF NORMAL OPER INCL THOSE
ORIGNINATING FROM VOLAT, RXN OR OXIDATION OF MATLS LISTED IN
INGREDS (SUPP DATA)
Disposal
Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSABLE CONTAINER OR
LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE
WITH FEDERAL, STATE AN D LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.